Biogas Online Anlyzer
Biogas On-line Analyzer
A complete wall-mounted biogas analysis system consists of a rack type biogas analyzer, metal case, and gas conditioning system. Biogas analyzer can be used for measurement of the concentration of CH4, CO2, H2S and O2 in sample gases simultaneously. It is based on the single source two beams non-dispersion infrared (NDIR) method for CH4, CO2, fuel cell method (ECD) for H2S and O2. The general application is landfill, anaerobic digestion and other fermentation Processes.
- Up to 4 gases measurement with combination of NDIR and ECD gas sensor technology
- Simple construction with pulsable infrared source and two beams technology
- Constant temperature control for gas bench for high stability
- 320*240 LCD with menu operation. Repeatability: ±0.5% FS
- Linearity: ±1% FS
สอบถามข้อมูลและโปรโมชั่นเพิ่มเติม ได้ที่ คุณพัดสนีย์ โทร.0-2969-0130-1 ต่อ 106
|
Meansure Gas
|
Meansure Method
|
Meansure Rag
|
Resolution
|
Presition
|
Error
|
| CO2 | NDIR | 50% | 0.01% |
<=2%FS
|
<=2%
|
| CO4 | NDIR | 100% | 0.01% |
<=2%FS
|
<=2%
|
| H2O | ECD | 9999PPM | 1PPM |
<=3%FS
|
<=2%
|
| O2 | ECD | 25% | 0.01% |
<=3%FS
|
<=2%
|
|
Gas Flow
|
0.7 ~ 1.2 L/min |
| Pressure of gas inlet | <1Bar |
| Sampling gas requirement | Remove water vapor, dust(<1um) and oil etc. |
| Response Time | <15s (NDIR) |
| Warm-up time | 15min Communication port RS232(optional) |
| Output | 4~20 mA(according to the requirement) |
| Work temperature | 0~50℃ |
| Relative humidity | 5~85% |
| Ambient air pressure | 86~108kPa |
| Power supply | 220V±44V AC 50Hz±1Hz |
| Dimension | 483mm×373mm×140mm(W×L×H) |
| Weight | 12kg |
PC –based Recorder is a device that allows PC can act as the Recorder machine PC to read the measurement from external devices such as% CH4,% CO2,% O2, H2S, etc., then the measured values are processed
- RealTimeDisplay Shows the values measured in the number format to display a Real Time Computer.
- RealTimeTrend Graph Shows a measured value in the form of Real Time Trend Graph made aware of changes in the measure through time
- Recorder File
- Continuous Data File in the form to the Hard disk with the date and time display marked.
- Information contained in the File can bring back the display numbers, Plot Trend Graph print Out information on the Printer
- Convert File Program to share with others, such as Microsoft Word, Excel.
Specifications
|
Input
|
Expandable to 24 channels( with EX24 Module) |
| Input type Programmable | Thermocouple (R,S,K,E,J,T,B), RTD(PT100), 0-10 VDC, 0-5 VDC, 0-100 mVDC, 0-20 mA, 0-40 mA |
| A/D Converter | 24 Bits |
| Digital Input | 4 Channels,24VDC ,Opto Isolated |
| Digital Output | 4 Channels, NPN Open Collector |
| Output | 4~20 mA(according to the requirement) |
| Protocol | Modbus Ascii, Modbus RTU, Ascii Command |
| Power Supply | 110 VAC, 220 VAC (12 VDC, 24 VDC Optional) |
| Ambient Temperature | 0-50 °C |
| Comm.Port | RS-232 , RS-485 (Isolated), RS-232 to RS-485 |
| Converter build in | Mounting DIN rail |
| Dimension | W160 × H90 × D60 mm |
| Ordering Information | Specify Power Supply |
| Example | AI210/220 VAC |
Specifications
|
Operating Mode
|
RS-232, RS-485, RS-422 |
| Data Ratee | Up to 57.6 Kbps. |
| Data format | 8 bits, None parity bits, 1 stop bits |
| Communication | RF 2.4 GHz |
| Range | 1.6 Km. Outdoor, 100 m. Indoor (for antenna gain > 15 dBi) |
| Power Supply | 110 VAC, 220 VAC, 24 VDC, 110 VDC, 125 VDC |
| Mounting | Wall or DIN Rail |
| Dimension | W50 × H70 × D60 mm. |