• Thai (ภาษาไทย)
  • English (United Kingdom)

Biogas Online Anlyzer

 

Biogas On-line Analyzer

A complete wall-mounted biogas analysis system consists of a rack type biogas analyzer, metal case, and gas conditioning system. Biogas analyzer can be used for measurement of the concentration of CH4, CO2, H2S and O2 in sample gases simultaneously. It is based on the single source two beams non-dispersion infrared (NDIR) method for CH4, CO2, fuel cell method (ECD) for H2S and O2. The general application is landfill, anaerobic digestion and other fermentation Processes.

  • Up to 4 gases measurement with combination of NDIR and ECD gas sensor technology
  • Simple construction with pulsable infrared source and two beams technology
  • Constant temperature control for gas bench for high stability
  • 320*240 LCD with menu operation. Repeatability: ±0.5% FS
  • Linearity: ±1% FS

สอบถามข้อมูลและโปรโมชั่นเพิ่มเติม ได้ที่ คุณพัดสนีย์ โทร.0-2969-0130-1 ต่อ 106

Specifications

Meansure Gas
Meansure Method
Meansure Rag
Resolution
Presition
Error
CO2 NDIR 50% 0.01%
<=2%FS
<=2%
CO4 NDIR 100% 0.01%
<=2%FS
<=2%
H2O ECD 9999PPM 1PPM
<=3%FS
<=2%
O2 ECD 25% 0.01%
<=3%FS
<=2%
Gas Flow
0.7 ~ 1.2 L/min
Pressure of gas inlet <1Bar
Sampling gas requirement Remove water vapor, dust(<1um) and oil etc.
Response Time <15s (NDIR)
Warm-up time 15min Communication port RS232(optional)
Output 4~20 mA(according to the requirement)
Work temperature 0~50℃
Relative humidity 5~85%
Ambient air pressure 86~108kPa
Power supply 220V±44V AC 50Hz±1Hz
Dimension 483mm×373mm×140mm(W×L×H)
Weight 12kg

PC –based Recorder

PC –based Recorder is a device that allows PC can act as the Recorder machine PC to read the measurement from external devices such as% CH4,% CO2,% O2, H2S, etc., then the measured values are processed

  • RealTimeDisplay Shows the values measured in the number format to display a Real Time Computer.
  • RealTimeTrend Graph Shows a measured value in the form of Real Time Trend Graph made aware of changes in the measure through time
  • Recorder File
    • Continuous Data File in the form to the Hard disk with the date and time display marked.
    • Information contained in the File can bring back the display numbers, Plot Trend Graph print Out information on the Printer
    • Convert File Program to share with others, such as Microsoft Word, Excel.

Specifications

Input
Expandable to 24 channels( with EX24 Module)
Input type Programmable Thermocouple (R,S,K,E,J,T,B), RTD(PT100), 0-10 VDC, 0-5 VDC, 0-100 mVDC, 0-20 mA, 0-40 mA
A/D Converter 24 Bits
Digital Input 4 Channels,24VDC ,Opto Isolated
Digital Output 4 Channels, NPN Open Collector
Output 4~20 mA(according to the requirement)
Protocol Modbus Ascii, Modbus RTU, Ascii Command
Power Supply 110 VAC, 220 VAC (12 VDC, 24 VDC Optional)
Ambient Temperature 0-50 °C
Comm.Port RS-232 , RS-485 (Isolated), RS-232 to RS-485
Converter build in Mounting DIN rail
Dimension W160 × H90 × D60 mm
Ordering Information Specify Power Supply
Example AI210/220 VAC

Wirless RS-232/485 is a device used to connect RS-232/485 signals via radio signals. The cost of installation without hardwired.

Specifications

Operating Mode
RS-232, RS-485, RS-422
Data Ratee Up to 57.6 Kbps.
Data format 8 bits, None parity bits, 1 stop bits
Communication RF 2.4 GHz
Range 1.6 Km. Outdoor, 100 m. Indoor (for antenna gain > 15 dBi)
Power Supply 110 VAC, 220 VAC, 24 VDC, 110 VDC, 125 VDC
Mounting Wall or DIN Rail
Dimension W50 × H70 × D60 mm.

Click image to open!